Nilima Design Associates

Home / Insights

Field notes &
case studies.

Real assessments, real findings — a record of how we actually work, not just what we say we do.

Case Study — NDT

Structural Condition Assessment Using Rebound Hammer Test

G+2 Residential Building — Garden Reach, Kolkata

A structural condition assessment and Non-Destructive Testing of a G+2 residential building, evaluating concrete surface hardness across columns, beams and the lift wall without damaging any structural members.

Read case study

Case Study — Structural Design

G+7 Structural Design – Infrastructure Project, Agartala

G+7 Infrastructure Building — Agartala, Tripura

Structural engineering and design services for a G+7 RCC framed infrastructure project in Agartala, Tripura, designed considering Seismic Zone V requirements.

Read case study

Case Study — Structural Health Assessment

Naihati Railway ROH Shed Structural Health Assessment

Structural Health Assessment & NDT of Railway ROH Shed, Naihati

An integrated structural health assessment of a Railway ROH Shed PEB structure at Naihati, combining steel inspection, non-destructive testing and concrete assessment to identify areas requiring rehabilitation.

Read case study

Case Study — Structural Assessment

Structural Stability & NDT Assessment of G+2 School Building

G+2 School Building with Auditorium — GyanDeep Vidyapith, Egra

A structural stability assessment of a G+2 school building with an auditorium in Purba Medinipur, combining visual inspection, Rebound Hammer, UPV, carbonation and reinforcement detection testing.

Read case study

Case Study — Structural Health Assessment

Structural Health Assessment of G+2 Housing Complex — BPCL Haldia

Structural Stability & NDT Assessment — BPCL Haldia Housing Complex

A structural health assessment of a G+2 residential building at BPCL Haldia, combining visual inspection, Rebound Hammer, UPV, carbonation testing and rebar scanning to identify concrete deterioration and rehabilitation requirements.

Read case study

Case Study — Post-Fire Structural Assessment

Post-Fire Structural Health Assessment of G+1 UCO Bank Building

Structural Health Checkup — UCO Bank, Bilkanda Branch

A post-fire structural health assessment of the G+1 UCO Bank Bilkanda Branch, combining visual inspection, Rebound Hammer, UPV, carbonation testing and rebar scanning to identify fire-related deterioration and rehabilitation requirements.

Read case study

Geophysical Investigation — VES Survey

Vertical Electrical Sounding (VES) Survey for Subsurface Investigation

Geophysical Investigation for Preliminary Groundwater Exploration and Subsurface Assessment

Explore how Vertical Electrical Sounding (VES) uses electrical resistivity measurements to investigate probable subsurface layers, support preliminary groundwater exploration, and guide further site investigations.

Read case study